Abstract
Different results have been reported on the internal colonization of Cone Morse connections under in vitro dynamic loading. The aim of the present in vitro study was to evaluate the bacterial leakage in Cone Morse implant-abutment connections, both under loaded and unloaded conditions.
A total of 20 implants with a Cone Morse taper internal connection were used in this study. Ten were loaded under a special testing equipment (Test Group), while 10 were left unloaded (Control Group). The inner part of all implants was inoculated with 0.1 μl of a viable
In the unloaded assemblies, bacterial contamination was found in 2 out of 10 implant-abutment junctions, on the 12th and 13th days. In the loaded implant-abutment connections, bacterial contamination was found in 2 out of 10 implant-abutment assemblies, on the 13th and on the 14th days.
The resistance of the Cone Morse implant-abutment junction reported in the literature and confirmed in the present study, where no differences in the percentages of microbial leakage were found in assemblies unloaded and in those subjected to a dynamic loading procedure, could help to explain the histological results in man of a lack of peri-crestal bone resorption in Cone Morse implants, placed below the level of the alveolar crest.
J Appl Biomater Funct Mater 2015; 13(4): e367 - e371
Article Type: ORIGINAL RESEARCH ARTICLE
DOI:10.5301/jabfm.5000247
Authors
Domenico Tripodi, Simonetta D’Ercole, Flavia Iaculli, Adriano Piattelli, Vittoria Perrotti, Giovanna IezziArticle History
- • Accepted on 31/05/2015
- • Available online on 27/11/2015
- • Published online on 18/12/2015
Disclosures
This article is available as full text PDF.
Introduction
The presence of an implant-abutment junction (IAJ) has been correlated with the presence of microorganisms (1). These bacteria may harbor inside the microgaps that can be found in the assemblies and they have been reported to be the cause of the inflammation of the soft tissues (abutment Infiltrated Connective Tissue or ICT) facing the IAJ, potentially producing a bone resorption of the surrounding pericrestal bone (2-3-4-5). Bacterial migration has been correlated with tightening torque forces, micromovements of the different components during the masticatory cycles and the accuracy of the fit between implant and abutment (1). Even if the Cone Morse implant-abutment connection is considered to be the most stable and the most capable to resist penetration of microorganisms when compared with flat-to-flat or tube-in-tube connections, their possible bacterial colonization is not yet well understood (6, 7). In all implant-abutment different connections the size of the IAJ microgaps can be increased during the loading of the assemblies (2, 8, 9), introducing a so-called pumping effect (10). Higher quantities of microorganisms have been reported for loaded than unloaded external hexagon and internal hexagon implants (9). On the other hand, a minimal contamination has been reported for Cone Morse connections (2, 11). Different results have been reported on the internal colonization of Cone Morse connections under in vitro dynamic loading. do Nascimento et al (9) found no significant differences in the amount of bacteria, comparing unloaded and loaded groups, while, on the contrary, Koutouzis et al (10) found that the bacterial penetration was influenced by the loading conditions. One of 20 assemblies was found to be colonized by
Methods and materials
A total of 20 implants with a Cone Morse taper internal connection (Universal II CM, Implacil, De Bortoli, Sao Paulo, Brasil) were used in this in vitro study. Ten were loaded under a special testing equipment (Test Group), while 10 were left unloaded (Control Group). To simulate cyclic loading and to mimic intraoral conditions, the Test implants were embedded in autopolymerizing acrilic resin with a custom-made stainless steel ring form. The implants were positioned using a parallelometer to ensure uniform alignment of all specimens. The implants were positioned so that the cyclic fatigue load was applied to the long axis of the implants. All embedded implants were sterilized by autoclave for 15 minutes at 121°C. After several trials, 0.1 μl was determined to be the ideal quantity of bacterial suspension for inoculation in the implant systems.
Abutment connected to the implant at 30 N cm.
Implant/abutment immersed in nutrient solution, drawn by sterile syringe and analyzed by culture method.
(
Results
The frequencies of contamination in both tested groups were shown in
Bacterial leakage in loaded and unloaded implants
Implants | Bacterial species | % of contamination | Days | Total |
---|---|---|---|---|
Loaded |
|
2 out of 10 | 13th and 14th days | 2 contaminated samples out of 10 |
Unloaded |
|
2 out of 10 | 12th and 13th days | 2 contaminated samples out of 10 |
Discussion
A gap of 1-5 microns has been reported to be present, in retrieved human implants, between the implant and the healing screw, and this space was found to be filled by bacteria and calculus (12). Bacteria were also present inside the most apical portion of the hollow part of the implant (12). In another histological study on retrieved human implants, it has been reported that bacteria were often present between the implant and the abutment and in the internal portion of the implants (13). These results, with the finding of hollow spaces, in screw-retained abutments, between the implant and abutment components with the presence of fluids and bacteria inside the internal hollow cavities of the implants, serve to validate, in man, the results obtained from in vitro studies or animal experiments (12). Moreover, in retrieved human implants, an inflammatory infiltrate was present below the implant-abutment microgap (12), and, in an experimental study in monkeys, many inflammatory cells were found below the implant-abutment microgap (5). There is evidence that with cyclic loading the microgap can increase in size, especially in external hexagon implants, facilitating the flow of fluids and bacteria (6, 9, 13-14-15). The results of the present study did not agree with the statement that overall loaded implants showed higher bacterial counts than unloaded implants (9). The present data may reflect the possible differences in the precision fit, in the degrees of taper and in the internal connection features of the implant components in the different implant systems (10, 14, 16). The reported average misfits between implant components vary greatly, from 1 to 100 microns (9). The occlusal loading of the implants produces bending forces and/or micromovements within the implant systems (9) increasing the microgap and promoting a higher fluid and bacteria infiltration (15), especially if imprecise machining of implant components or improper male-female adaptation exist (17). Cone Morse connections have been proposed to get a better stability, with reduced micromovements, of the components, providing a better bacterial seal (18). The bacterial microleakage can, probably, be reduced by obtaining an optimal component fit, a reducing or absence of micromovements, and a minimal prosthetic misfit (19-20-21-22-23-24-25-26-27-28). The length of the IAJ in Cone Morse implant-abutment assemblies could be a reason for the reported differences in the bacterial leakage (14). Implants that use mechanical frictional abutments seem to present precise adaptation in the deeper inner portions of the system, resulting in reduced micromovements (9).
Conclusion
The resistance of the Cone Morse IAJ reported in the literature and confirmed in the present study, where no differences in the percentages of microbial leakage were found in assemblies unloaded and in those subjected to a dynamic loading procedure, could help to explain the histological results in man of a lack of peri-crestal bone resorption in Cone Morse implants, placed below the level of the alveolar crest.
Acknowledgment
The Authors gratefully acknowledge the help of Donato Di Iorio, D.D.S., Ph.D., for the specimens preparation.
Disclosures
-
1.
Silva-Neto JP Prudente MS Carneiro TA Nóbilo MA Penatti MP Neves FD Micro-leakage at the implant-abutment interface with different tightening torques in vitro. 2012 20 5 581 587 -
2.
Koutouzis T Gadalla H Kettler Z Elbarasi A Nonhoff J The role of clohexidine on endotoxin penetration to the implant-abutment interface (IAI). 2015 17 3 476 82 -
3.
Hermann JS Schoolfield JD Schenk RK Buser D Cochran DL Influence of the size of the microgap on crestal bone changes around titanium implants. 2001 72 10 1372 1383 -
4.
Persson LG Lekholm U Leonhardt A Dahlén G Lindhe J Bacterial colonization on internal surfaces of Brånemark system implant components. 1996 7 2 90 95 -
5.
Piattelli A Vrespa G Petrone G Iezzi G Annibali S Scarano A Role of the microgap between implant and abutment: a retrospective histologic evaluation in monkeys. 2003 74 3 346 352 -
6.
Harder S Podschun R Grancicova L Mehl C Kern M Analysis of the intraimplant microflora of two-piece dental implants. 2013 17 4 1135 1142 -
7.
Aloise JP Curcio R Laporta MZ Rossi L da Silva AM Rapoport A Microbial leakage through the implant-abutment interface of Morse taper implants in vitro. 2010 21 3 328 335 -
8.
Pimentel AC Manzi MR Sartori SG da Graça Naclério-Homem M Sendyk WR In vivo effectiveness of silicone gel sheets as barriers at the inner microgap between a prosthetic abutment and an external-hexagon implant platform. 2014 29 1 121 126 -
9.
do Nascimento C Miani PK Pedrazzi V et al. Leakage of saliva through the implant-abutment interface: in vitro evaluation of three different implant connections under unloaded and loaded conditions. 2012 27 3 551 560 -
10.
Koutouzis T Mesia R Calderon N Wong F Wallet S The effect of dynamic loading on bacterial colonization of the dental implant fixture-abutment interface: an in vitro study. 2014 40 4 432 7 -
11.
Larrucea Verdugo C Jaramillo Núñez G Acevedo Avila A Larrucea San Martín C Microleakage of the prosthetic abutment/implant interface with internal and external connection: in vitro study. 2014 25 9 1078 1083 -
12.
Orsini G Fanali S Scarano A Petrone G di Silvestro S Piattelli A Tissue reactions, fluids, and bacterial infiltration in implants retrieved at autopsy: a case report. 2000 15 2 283 286 -
13.
Scarano A Assenza B Piattelli M et al. A 16-year study of the microgap between 272 human titanium implants and their abutments. 2005 31 6 269 275 -
14.
Steinebrunner L Wolfart S Bössmann K Kern M In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. 2005 20 6 875 881 -
15.
da Silva-Neto JP Nóbilo MA Penatti MP Simamoto PC Jr das Neves FD Influence of methodologic aspects on the results of implant-abutment interface microleakage tests: a critical review of in vitro studies. 2012 27 4 793 800 -
16.
Passos SP Gressler May L Faria R Özcan M Bottino MA Implant-abutment gap versus microbial colonization: Clinical significance based on a literature review. 2013 101 7 1321 1328 -
17.
Coelho AL Suzuki M Dibart S DA Silva N Coelho PG Cross-sectional analysis of the implant-abutment interface. 2007 34 7 508 516 -
18.
Jaworski ME Melo AC Picheth CM Sartori IA Analysis of the bacterial seal at the implant-abutment interface in external-hexagon and Morse taper-connection implants: an in vitro study using a new methodology. 2012 27 5 1091 1095 -
19.
Al-Jadaa A1 Attin T Peltomäki T Schmidlin PR Comparison of three in vitro implant leakage testing methods. 2015 26 4 e1- 7 -
20.
Torres JH Mechali M Romieu O et al. Development of a new quantitative gas permeability method for dental-implant abutment connection tightness assessment. 2011 10 28 -
21.
do Nascimento C Miani PK Pedrazzi V Muller K de Albuquerque RF Jr Bacterial leakage along the implant-abutment interface: culture and DNA Checkerboard hybridization analyses. 2012 23 10 1168 1172 -
22.
Duarte ARC Rossetti PHO, Rossetti LMN, Torres SA, Bonachela WC. In vitro sealing ability of two materials at five different implant-abutment surfaces. 2006 77 11 1828 1832 -
23.
Rismanchian M Hatami M Badrian H Khalighinejad N Goroohi H Evaluation of microgap size and microbial leakage in the connection area of 4 abutments with Straumann (ITI) implant. 2012 38 6 677 685 -
24.
Baggi L Di Girolamo M Mirisola C Calcaterra R Microbiological evaluation of bacterial and mycotic seal in implant systems with different implant-abutment interfaces and closing torque values. 2013 22 4 344 350 -
25.
Assenza B Tripodi D Scarano A et al. Bacterial leakage in implants with different implant-abutment connections: an in vitro study. 2012 83 4 491 497 -
26.
D’Ercole S Scarano A Perrotti V et al. Implants with internal hexagon and conical implant-abutment connections: an in vitro study of the bacterial contamination. 2014 40 1 30 36 -
27.
Degidi M Piattelli A Shibli JA Perrotti V Iezzi G Early bone formation around immediately restored implants with and without occlusal contact: a human histologic and histomorphometric evaluation. 2009 24 4 734 739 -
28.
Degidi M Perrotti V Shibli JA Novaes AB Piattelli A Iezzi G Equicrestal and subcrestal dental implants: a histologic and histomorphometric evaluation of nine retrieved human implants. 2011 82 5 708 715
Authors
- Tripodi, Domenico [PubMed] [Google Scholar]
- D’Ercole, Simonetta [PubMed] [Google Scholar]
- Iaculli, Flavia [PubMed] [Google Scholar] , * Corresponding Author ([email protected])
- Piattelli, Adriano [PubMed] [Google Scholar]
- Perrotti, Vittoria [PubMed] [Google Scholar]
- Iezzi, Giovanna [PubMed] [Google Scholar]
Affiliations
-
Department of Medical, Oral and Biotechnological Sciences, University “G. D’Annunzio” of Chieti-Pescara, Chieti - Italy
Article usage statistics
The blue line displays unique views in the time frame indicated.
The yellow line displays unique downloads.
Views and downloads are counted only once per session.